Building Science 101 / Pressure

Lesson 5 of 14

Pressure

Pressure Measurements

Pressure visualized

  • 1" of water column in pascals is - 250 pascals
  • Pressure is commonly measured in Pascal's
  • 1 Pascal = .004 inch of water
    (4 Thousandths, a little higher than the thickness of 1 human hair)
  • If you are drinking with a straw, and pull your drink up the
    straw only 1” you have created -250 pascals in the straw.Illustration: Pressure Measurements

Testing pressures visualized

  • Buildings are tested at -50 Pascal's
    (1/5th the pressure of the 1” water in a straw)
  • Ducts are tested at 25 pascals, even though duct work normally operates with much higher pressures.
  • Blower door measurements are written like 900 CFM50
  • Duct testing measurements are written like 60 CFM25

Illustration: Testing pressures visualized


The Almighty “N” Factor

A Blower door measurement (at -50 pascals) can be converted to a Natural infiltration number.

Story's above Grade determines the conversion number.

Stories NY N – factor
1 19
2 15.4
3 13.7

CFMn = CFM50 / N ACHn = ACH50 / N

If a 2 story home with 2,200 Sq ft had 8’ Ceilings and a volume of 17,600 Cu Ft…
A Blower door test result for that home was = 2053 CFM50

Its natural leakage could be estimated by 133CFMn = 2053 / 15.4
ACH50 = CFM50 x 60/volume So 7ACH50 = 2053 * 60 / 17,600

Its ACHn is ACH50/N .45 = 7 / 15.4


Typical example; 2,200 sq ft, 2 story home with 8’ ceilings

Illustration: Typical example;  2,200 sq ft, 2 story home with 8’ ceilings

The recently departed 2010 NYS Energy Conservation Construction Code required the home to be equal to or under 7 ACH50

  • —2053CFM50 = Required Blower Door
  • —133CFMnat = or 133 basketballs, every min of every hour in the winter !!
  • —113 square inch hole or 10.6” x 10.6” (Effective Leakage Area)

Comparing pressure / airflow measurements

The same 2,200 sq ft, 2 story home with 8’ ceilings
NYS 2016 energy code and Passive House

Illustration: Comparing pressure / airflow measurements

The effective leakage area is the size of the hole equal to the sum of every little one usual found in construction.