Pressure Measurements
Pressure visualized
- 1" of water column in pascals is - 250 pascals
- Pressure is commonly measured in Pascal's
- 1 Pascal = .004 inch of water
(4 Thousandths, a little higher than the thickness of 1 human hair) - If you are drinking with a straw, and pull your drink up the
straw only 1” you have created -250 pascals in the straw.
Testing pressures visualized
- Buildings are tested at -50 Pascal's
(1/5th the pressure of the 1” water in a straw) - Ducts are tested at 25 pascals, even though duct work normally operates with much higher pressures.
- Blower door measurements are written like 900 CFM50
- Duct testing measurements are written like 60 CFM25
The Almighty “N” Factor
A Blower door measurement (at -50 pascals) can be converted to a Natural infiltration number.
Story's above Grade determines the conversion number.
| Stories | NY N – factor |
| 1 | 19 |
| 2 | 15.4 |
| 3 | 13.7 |
CFMn = CFM50 / N ACHn = ACH50 / N
If a 2 story home with 2,200 Sq ft had 8’ Ceilings and a volume of 17,600 Cu Ft…
A Blower door test result for that home was = 2053 CFM50
Its natural leakage could be estimated by 133CFMn = 2053 / 15.4
ACH50 = CFM50 x 60/volume So 7ACH50 = 2053 * 60 / 17,600
Its ACHn is ACH50/N .45 = 7 / 15.4
Typical example; 2,200 sq ft, 2 story home with 8’ ceilings
The recently departed 2010 NYS Energy Conservation Construction Code required the home to be equal to or under 7 ACH50
- 2053CFM50 = Required Blower Door
- 133CFMnat = or 133 basketballs, every min of every hour in the winter !!
- 113 square inch hole or 10.6” x 10.6” (Effective Leakage Area)