Where the Heat Goes

A house in winter leaks heat all the time. The heating system only replaces what leaks out. Change the house and watch how much heat leaves, and by which route.

Cross-section of a house showing heat leaving through the attic, walls, windows, air leaks and leaky attic ducts. RETURN SUPPLY 70°F inside Heating system adds 0 BTU/h 15°F outside Attic 0 Duct leaks 0 Walls 0 Cold air pulled in low Warm air leaking out 0 Windows 0
Heat conducted through surfaces Warm air leaking out naturally Cold air leaking in naturally, equal to what leaks out Heated duct air lost to the attic Outdoor air pulled in to replace it, square for square Every shape carries the same amount of heat. One shape per second is 500 BTU per hour.

Change the house

-30°F60°F

Measured in CFM at 50 pascals. The ticks mark 3, 5 and 8 air changes per hour (ACH50) for this house: 3 is the code limit today, 5 was the limit for years, and 8 is what real houses often measure.

Triple paneSingle pane
R-4R-40
R-8R-60

Ducts in the attic

Duct leakage test result, in CFM at 25 pascals. The code limit of 4 per 100 sq ft would be 80 for this house.

Heat leaving right now

0 BTU per hour

To hold 70°F, the heating system has to add exactly this much. Anything bigger just shuts off sooner.

By route

Example house: 2,000 sq ft on one floor, 8 ft ceilings, 300 sq ft of glass, 70°F indoors. Steady-state math: surfaces lose area × temperature difference ÷ R-value, and air leaks lose 1.1 × CFM × temperature difference. Natural leakage is the blower door CFM50 divided by the LBL n-factor, which depends on climate zone, number of stories and wind shielding. Ducts: all leakage is treated as supply air lost to a vented attic at 120°F, and the test number is used as the leak rate while the blower runs. The house pulls in the same amount of outdoor air to replace it. Floor and foundation, doors, heat conducted through duct walls, sunshine and heat from people and appliances are left out to keep the picture simple, so treat the numbers as an illustration, not a load calculation.