Where the Heat Goes
A house in winter leaks heat all the time. The heating system only replaces what leaks out. Change the house and watch how much heat leaves, and by which route.
Change the house
Measured in CFM at 50 pascals. The ticks mark 3, 5 and 8 air changes per hour (ACH50) for this house: 3 is the code limit today, 5 was the limit for years, and 8 is what real houses often measure.
Ducts in the attic
Duct leakage test result, in CFM at 25 pascals. The code limit of 4 per 100 sq ft would be 80 for this house.
Heat leaving right now
To hold 70°F, the heating system has to add exactly this much. Anything bigger just shuts off sooner.
By route
Example house: 2,000 sq ft on one floor, 8 ft ceilings, 300 sq ft of glass, 70°F indoors. Steady-state math: surfaces lose area × temperature difference ÷ R-value, and air leaks lose 1.1 × CFM × temperature difference. Natural leakage is the blower door CFM50 divided by the LBL n-factor, which depends on climate zone, number of stories and wind shielding. Ducts: all leakage is treated as supply air lost to a vented attic at 120°F, and the test number is used as the leak rate while the blower runs. The house pulls in the same amount of outdoor air to replace it. Floor and foundation, doors, heat conducted through duct walls, sunshine and heat from people and appliances are left out to keep the picture simple, so treat the numbers as an illustration, not a load calculation.