Building science on Long Island since 2006
Homes designed, calculated and tested for comfort.
Energy code design, HERS ratings, Manual J, S and D, and the testing that proves the house was built that way. One person does all of it, so nothing gets lost between the plan and the finished home.
Building or renovating?
For builders and architects who need a house to meet the energy code. We review the plans, tell you what has to change, rate the home, and run the blower door and duct tests the code calls for.
How code compliance worksUncomfortable, or buying equipment?
For homeowners holding three quotes with three different sizes. We calculate what your house needs, room by room, so you know the right size before you sign anything.
Get the right size for your houseDesign it. Calculate it. Test it.
Most houses get these three jobs from three different companies who never talk to each other. Here they are one job.
1. Design
Energy code and HERS ratings
RESNET-certified ratings for New York energy code, ENERGY STAR and town-mandated HERS index targets. We work from your plans, before anything is built.
Ratings and code design2. Calculate
Manual J, S and D
Room-by-room heating and cooling loads, equipment selection checked against the manufacturer's data, and a duct design that delivers the air. Room-by-room reports start at $250.
Prices and ordering3. Test
Blower door, duct leakage, thermal imaging
The measurements that show whether the house was built the way it was drawn. You get the numbers, what they mean, and what to fix if it falls short.
What each test showsIn the classroom
Your load calculation is done by the person who taught the others.
Glenn has taught Manual J software in classrooms from California to Long Island, and energy code to the officials who enforce it.
Only here
Watch your own house lose heat.
A load calculation is fifty pages of numbers. Yours also comes with a house code. Type it in and the page shows your home on its coldest design day: how much heat leaves through the walls, the windows, the roof, the air leaks and the ducts.
After we test the finished house, you get a second code with the measured numbers, so you can compare the design with what was built.
A real 7,500 sq ft home at 17°F outside.
Case file
7,000 square feet.
3 tons of cooling.
The load calculation said a 7,000 square foot house needed three tons of cooling. Everyone balked. The usual answer for a house that size is several times more.
The owner believed the math, and the contractor installed what was specified. People who visit can't believe how comfortable the house is.
Read the case fileGlenn Hooper does the work himself.
He spent years running job sites for a Long Island builder, then fixed his own house when winter humidity fell to 9 percent. That repair took an afternoon and started Residential Energy Conservation in 2006.
The whole story- RESNET HERS Rater
- BPI Building Analyst, Shell and Heating Specialist
- Passive House Rater
- ANSI Level 1 Thermographer
- New York State trainer, Manual J 8th Edition software