Stack Effect
Warm air (Red Arrows) leaving through the upper portion of the home, and below a neutral pressure plane, outside air is pulled in.
Depressurization
If there is leaky duct work in the attic, the air handler return will be “missing” the same amount of air that leaked into the attic.
Generally there is much more surface area of supply ducts in an attic as compared to return ducts. Since the air handler is pressurizing the supply ducts in the attic, it stands to reason that there will be a larger amount of air lost through the supply duct leakage. As the return ducts have a relativity small surface area, and the return ducts leakage rate much smaller, the system fan pressurizes the attic, while the return duct depressurizes the home even further.
Where will this missing air come from ?
If this is cooling season, remember from psychometrics what happens to warm moist air when it hits a cooler surface …
Air Flow in deeper detail
- Most homes are built too loose. Often they need humidification for comfort during the winter.
- We produce humidity. Showering, washing, cooking etc.
- Most of our incidental moisture is exfiltrated along with our heat.
- For every cubic foot of air lost, we have to pay to re-heat or cool another cubic foot of air that was puled in to replace it.
- What feels warmer 70˚ air at 75% RH or 70˚ air at 9% RH
- At one RH you might shiver in a breeze, and the other feel warm.
- What appliances use stack effect in a home and how can stack effect from the home compete with that process.
- When that moisture leaves, what damage could it be causing ?
This was an unused, unvented bath exhaust that was buried under the fiberglass insulation in the attic. The sheetrock had black mold, the sheathing above was also soaking wet.
Which will win 2
Depressurization from leaky attic air handler, adding stack loss against Domestic Hot water heater ?
The Natural Draft hot water heater will more than likely loose, especially on a cold flu pipe. A back-draft is when the home will become the chimney!
Measuring Air Flow
Common terms.
- ACH50 = Air changes per hour under 50 pascals.
- CFM50 = Cubic Feet per minute at 50pascals.
- CFMn = Cubic feet per minute under natural conditions.
- ACHn = air changes under natural conditions.
- CFM 25 = Cubic Feet per minute at 25pascals.
When trying to explain Cu Ft to my customers during a Home Performance Audit, I would tell them to imagine Basket balls 82 CFM = 82 Basketballs